Specialists in fire dampers and control systems
Safegard specialise in the niche area of smoke and fire control / containment within the ducted ventilation systems in a variety of large buildings, including hospitals, airports and multi-storey office blocks.
Featured Products
Compartmentalise fire zones and reduce the spread of smoke and fire.
Keep escape routes and fire-fighting access open.
Allow pressurisation and smoke extract by combined operation of dampers and fans.
Allow complex strategies (cause and effect).
Optional networking of panels to a central control and monitoring panel - up to 64 networked panels.
Safegard V5 is a CE marked, EMC and LVD compliant product.
Powerful and very flexible functionality accommodates any last minute changes to strategy, zones, damper quantities, references and descriptions etc and enables standardisation of software (no bespoke site specific versions required).
The Safegard EMB controls a number of smoke/fire dampers hard wired individually or in groups to this central control panel.
Dampers and control actuators may have differing control and monitoring requirements.
Purposely manufactured for the particular project to suit specific requirements.
Individually or collectively control/monitoring of dampers.
Wall mounted enclosures.
Used for the isolation of duct penetrations between fire compartments
• Fire dampers consist of housing, fire-resistant damper blade and release mechanism
• Casing made of galvanised sheet steel, damper blade made of special insulating material, damper blade shaft and push rod made of galvanised steel, bearings made of brass, seals made of polyurethane and elastomer
• Closed blade air leakage according to EN 1751, class 2
• Casing air leakage to EN 1751, class C
• Fire damper can be equipped with thermal fuse with 72°C release temperature
• Safegard EIS-FD-M is square / rectangle motorised
• Safegard EIS-FDC-M is circular motorised
• Fire damper casing is manufactured form galvanised steel, but on demand can be made from:
Galvanised Steel and Powder Coated
Stainless Steel
Stainless Steel and Powder Coated
ATEX
Maintenance
At the core of Safegard Systems is our commitment to delivering unsurpassed levels of customer service. In line with this and after handover of your Safegard System, we provide preventative maintenance contracts to ensure continued optimum performance of your life safety system. You will have the choice of Standard or Standard Plus preventative maintenance contracts to choose from. Preventative Maintenance Contracts available directly from Safegard Systems for both Irish and UK customers.
Our projects
The prestigious Carton House Hotel recently reopened as the “Fairmont Carton House Hotel” after the extensive restoration and luxury refurbishment of the main Carton House, Spa & Wellness Centre. Situated in the heart of 1100 acres of sweeping parkland, ancient woodlands, lakes and the river Rye in Co Kildare.
The Royal Victoria Hospital treats more than 80,000 people as inpatients and 350,000 people as outpatients every year.
Safegard Systems were approached to provide smoke & fire dampers for Pfizer Inc. who currently employ over 4,000 employees across 5 sites in the Republic of Ireland. The manufacturing giants have been in Ireland since 1969 and decided to upgrade and improve their premises.
With this particular project, there were a couple on non-standard installation details required. Pfizer utilised Safegard’s damper installation inspection & sign-off service to overcome this issue.
After commissioning was completed, it was reported that there was an issue with the system causing the fan to run when it was required not to. When Safegard attended the site to look into this issue, we discovered the client was trying to switching 230v through our panel which is not possible. This was not in place when the panel was commissioned.
After consulting with the client we suggested that we would arrange for a relay to be fitted externally to the panel to give us 24V to switch over the output they needed to send a run signal.
Safegard Systems can help provide solutions to any challenges that the client may come across.
The Hard Rock Hotel Dublin celebrates the pioneering artists of the past and present that have contributed to the city’s rich cultural heritage. Located on Lord Edward Street, The Hard Rock Hotel Dublin is one of the best hotels in Dublin city centre. The property features 120 luxurious guest bedrooms and suites furnished to an exceptionally high standard.
Earlier this year, Safegard Systems recently commissioned & supplied essential smoke fire dampers to one of Ireland’s largest food production facilities Emeri Nutrition.
Safegard Systems recently completed the supply and commissioning of smoke fire dampers and controls in a number of stylish new Maldron Hotels, including;
Safegard Systems where engaged to supply and commission the critical smoke fire damper safety system, along with the associated SmokeShield Dampers.
The Lennox Building has been designed with the well being and productivity of its members at its core. The building and its occupants are protected by a Safegard EMB damper control panel along with Safegard EIS dampers.
Safegard Systems where engaged to supply and commission critical fire and smoke safety systems in this Premium development.
A contemporary 300 bed hotel in the heart of Dublin, Safegard Systems where engaged to design, supply and commission the Smoke Fire Damper Control System .
Safegard V5 Control System and European Style Dampers:
The V5 panel is an intelligent control and monitoring system for the smoke fire dampers fitted throughout the hotel. The system monitors and commands particular dampers to open or close in affected zones during a fire. The control system quickly and effectively interfaces directly with the building's fire alarm systems and Building Management system. It also means that all of the dampers can be tested remotely on a regular basis, adhering to current building regulations and best practice and significantly reduces maintenance time and cost. The CE marked and ‘EIS’ rated automatic fire/smoke dampers throughout the development have been engineered to inhibit the spread of smoke and fire.
Safegard Systems design and supply systems to protect buildings and the occupants in the event of fire. Solutions are designed and supplied with the user in mind, providing innovative approaches that offer simple means of installation, operation and maintenance.
An €80 million building for the Trinity Business School at Trinity College Dublin was opened in May 2019. The six-storey building located on the city-centre campus will include an Innovation and Entrepreneurial hub, a 600 seat auditorium, smart classrooms with the latest digital technology and an executive education centre.
Steeped in history and tradition the Curragh Racecourse is one of Ireland’s premier flat racing venues and is considered to be one of the finest tracks in the world. The new Curragh redevelopment sees the creation of a top class facility on a par with the best anywhere in the world. The centrepiece of the redevelopment is a major new grandstand which includes corporate suites, restaurants, bars and superb viewing facilities. A new reception area incorporates a museum to celebrate the history and contribution of Irish racing.
Due for completion mid 2019 a large 20,000 pharmaceutical complex in Dunboyne is set to employ 400 people in high value jobs in the manufacturing of treatments for rare genetic diseases. The €400 million investment in this biotech facility is a major boost for Meath. Construction at the complex is due for completion in the middle of 2019
Contact us